1 member for "Carlow Concrete":

Company Type Contact
Carlow Concrete Supply Chain
View Profile

110 results for "Carlow Concrete":

Infill and Oversail Systems

Infill Walling Systems 

In multi-storey framed construction light steel external walling systems are used extensively to create a rapid dry building envelope on a range of building types and are an economic and efficient method of...


LSF Load-bearing Systems

LSF load-bearing structures have structural capability up to 15 storeys. Structures are generally formed as pre-panelised systems which are lighter and easier to erect than alternative building technologies. Structures are formed using wall and...


LSF Walling

Light steel frame components can be used as a direct replacement for structural walls as either fully load-bearing structures with external facades or as secondary components in load-bearing frames. These frames are formed from...


LSF Flooring

LSF components are used to form structural floors in load-bearing structures. LSF floors can also be used in volumetric modular construction where floors are formed from a double deck system of a floor and ceiling combination. Refer to...


LSF Interfaces

Key interfaces with other non-LSF elements are relevant to both load-bearing and non load-bearing systems. Interfaces need to be determined early in the design process to ensure requirements are captured and costed for. Interfaces with...


Elements Used in Conjunction with LSF

When forming LSF structures other components/elements are required to create the finished structure. These elements need to be considered at the early design stage: Substructure LSF structures can be built on various...


LSF and Hybrid Construction

For the purposes of this guide we define hybrid construction as systems that include a combination of hot rolled and cold rolled steel. This is generally in areas where additional hot rolled elements are required to enhance the performance...


Think On Top Of The Box

Located in a coastal location, this was a conversion of an existing 3 storey concrete frame building into 9 townhouses. Frameclad provided the SFS infill to form new external walls to the existing levels then added a self-supporting top floor...


Mitigating Risks in Residential Buildings

Light steel structures fully comply with the requirements of the Building Regulations and leading warranty providers. Performance covers structural, fire, acoustics, thermal, airtightness, weathertightness, shrinkage, programme and accuracy. Here...


Focus on Framing - Putting Steel at the Centre of Construction

Frank and forthright discussions were the order of the day at a recent Focus on Framing virtual roundtable, seeking to identify many of the key drivers for the specification and sustainability of light steel frame within the offsite...


 

Stay in touch:

Industry partners
Twitter 1 Jan